CAUTIONS!!! It could be life danger without proper earthing/grounding. Machine is equipped with two wire power cable only. !!!!!! No earthing wire, which is funny when producer say on warning sticker: "THE BODY OF MACHINE MUST BE GROUNDING RELIABLE!" There is no grounding screw on machine body either (as on some previous models). Mine is now replaced with 3-wire power cable and earthed for safe operations. Modification is seen on photo.
60
Comentarios (7)
Enviar
  • spletko Itested it thoroughly after modification and beside mentioned earthing security flaw it works really great and I can only recommend it (with due security mode as proposed).

    Reponder 2019-11-06 09:22:32
  • Joseph If I was to add a ground wire to mine do I just put a wire in from the plug to the yellow housing? Looks like your ground wire is connected to the circuit board?? Or is that the frame there?

    Reponder 2019-11-18 04:07:35
  • John Can anyone email an English language translation of the operating booklet as the one supplied is in Chinese thank you. johnkeithe@gmail.com

    Reponder 2019-11-28 07:32:47
  • sabatino I would like information

    Reponder 2019-12-05 04:06:05
  • sivtek ja

    Reponder 2019-12-27 10:50:14
  • mambo Hi!! could I please get information on how you exactly did this modification

    Reponder 2020-03-01 14:36:31
  • banggoodcom Just take care to replace the original cable (2 wires of 1.5mm²) by a cable with 3 wires of 1.5 mm² by conductors minimum. Never 0.5 or 0.75 mm² for exemple !!!
    The value of 1.5 mm² is engraved or painted on the cable itself.

    Reponder 2020-05-04 17:36:49